Service manual
2. Overhauling
2-10
SG05048
2.3.5 Mounting of generator main unit and engine on frame
Perform centering carefully, to avoid deviation in the horizontal leveling caused by
distortion of the frame or inaccurate mounting of the generator main unit and engine.
Running the machine without accurate centering may cause abnormal vibrations.
①
Generator main unit
②
Engine
③
Bracket
④
Bolt
⑤
Shim
⑥
Cushion rubber
⑦
Nut