Service manual
2. Overhauling
2-9
2.3.4 Assembly of flywheel housing and generator main unit frame (stator)
Handle the stator with care after fastening the engine flywheel and generator
coupling, to avoid damage to either the rotor or stator.
Tighten the connections to the specified torque.
For connection of flywheel housing and generator main unit frame (stator), coat
anti-corrosion agent “ METAL CLEAR” on the connecting faces to prevent rust and
corrosion.
Install the stator
1. Carefully push into the stator, preventing the stator and rotor from rubbing each other.
2. Install the flywheel housing and the stator, tightening the connecting bolts.
The bolts should be high tensile 7T or more.
3. Remove the angle wooden block from under the flywheel housing, and place the generator
main unit and engine horizontally.
Tightening torque of generator main unit frame (stator) connecting bolts. (See ④ of 2.3.1 Bolts)
SDG25S
-6A7
SDG45S
-6A6
SDG65S
-6A6
SDG100S
-6A6
SDG125S
-6A6
SDG150S
-6A6
Bolt size M10×1.5-25 M10×1.5-30 ← ← M10×1.5-30 ←
Quantity 12 ← ← ← ← ←
Tightening
torque
lbw
・
ft
[N
・
m]
(kgf
・
cm)
18
[24]
(245)
← ← ← ← ←
SG06060