Service manual

4. Troubleshooting
4-13
D Checking Rotary Rectifier (Diode)
Remove the silicon rectifiers (diode) of rotary rectifier, and then measure them with a tester.
SG06013
Note: Rotary rectifier has 3 pieces of silicon rectifiers of forward polarity at K side and 3 pieces
of silicon rectifier of reverse polarity at J side. Be care to distinguish the polarity.
(positive and negative)
E Checking Varistor
Disconnect the terminals of surge absorber, then measure the resistance value between both
terminals. Resistance value must be more than 100kΩ. (Range of tester×kΩ)
SG05092E
Normal part Defective part