CHART A
Independent Laboratory Testing BCI 2-Hour Life
Group Size “27” Batteries East Penn Gel and AGM vs. Competitor
This chart compares the cycles run until the battery capacity dropped to 50% of
the 15th cycle’s capacity (on discharges at the 2-hour rate to a 10.5-volt cutoff).
CHART B
Charging Current vs.Charging Time
Shown is the current needed to charge a battery from 0% to 90% state of charge
in a given time. Or time required to change a battery from 0% to 90% state
of charge at a given current. For example, to charge an 8G8D (curve H) to 90% in
3.5 hours, 100 amperes are required; at 35 amperes, it would take 10 hours
Hours
Initial Charging Current (Amperes)
A 8GU1, 8GU1H, 8AU1, 8AU1H
B 8G22NF, 8A22NF
C 8G24, 8A24
D 8G27, 8A27
E 8G30H, 8G31, 8G31DT, 8A30H, 8A31, 8A31DT
F 8GGC2, 8AGC2
G 8G4D, 8A4D
H 8G8D, 8A8D
B
A
C
D
E
F, G
H
East Penn AGM
East Penn Gel