Owner's manual
35
MK-101 Pro24 JCS MAINTENANCE
(A)
Increase cooling ow by releas-
ing the Flow Adjusting Clamp.
(B)
Reduce cooling ow by
Pressing down on the Flow
Adjusting Clamp.
If ow to the diamond blade requires adjustment, perform the following actions.
Flow Adjustment
Blade Dressing
NOTE:
Like most cutting instruments, a diamond blade performs best when it is dressed. Over time and use,
diamonds on the outer edge of the blade will become smoothed or “glazed” over. This will reduce
grinding efciency and may cause the blade to “wander” or bend giving the illusion of an alignment
problem. When this occurs, the blade will need to be dressed. The diamond blade can be dressed us-
ing the MK Dressing Stick (part number 152972) and by following the steps below.
(A)
Setup the MK101 for operation
(See Setup, Adjustment
and Operation).
(B)
Set the Adjustable Cutting
Guide to cut a 1/16-strip.
(C)
Position the Dressing Stick. Cut
the Dressing Stick 7 or 8
times to dress the Blade.