Installation Sheet
Table Of Contents
- ,HL111101G,
- GENERAL
- INSTALLATION TO OUTLET BOX
- STEP 1. Pull the wires out from the outlet box, and install mounting plate onto the outlet box using the (2) mounting screws.
- STEP 2. Fasten bare ground wire to ground wire from the wall outlet box (usually green or copper color) or connect ground wire to green screw on the mounting plate.
- STEP 3. Connect the neutral (white) fixture wire coming from the fixture base to neutral (usually white) outlet wire. Fasten both wires together with a plastic wire nut and tightly wrap the wire nut with electrical tape.
- STEP 4. Repeat the previous step with the hot (black wires). Make sure there are no exposed wires or strands that could cause a dangerous short circuit.
- FAILURE TO CONNECT THE APPROPRIATE WIRES CORRECTLY COULD RESULT IN SEROIUS INJURY OR DEATH!
- STEP 5. Carefully place connections back into the outlet box.
- STEP 6. Place Back plate over the mounting plate and secure with set screws.
- STEP 7. Screw in decorative plug into the bottom of the backplate.
- STEP 1. Lift glass shade up over the glass fitter and secure with thumb screws.
- STEP 8. Install the lamp(s). The fixture is rated for 60 watt G lamp.
- DO NOT EXCEED RECOMMENDED WATTAGE!
- STEP 9. Restore power to the circuit at breaker or fusebox.
- INSTALLATION USING STEM/PLUG
- STEP 2. Remove the mounting plate from the backplate
- STEP 3. Determine the location for the lamp. Using the mounting plate as a template, mark the location of the holes for the wall anchors.
- STEP 4. Drill the appropriate size holes for the wall anchors (holes should be slightly smaller than the size of the anchors).
- STEP 5. Install the wall anchors, and anchor screws.
- STEP 6. Install the mounting plate to the anchor screws using the key slot
- STEP 7. Attach stem to the bottom of the backplate, and feed cord through the stem.
- STEP 8. Connect the cord to the stem using the procedures outlined in steps 2-4 of the outlet box installation above
- FAILURE TO CONNECT THE APPROPRIATE WIRES CORRECTLY COULD RESULT IN SEROIUS INJURY OR DEATH!
- STEP 9. Place the fixture to the wall over the mounting plate and secure using the set screws.
- STEP 10. Lift glass shade up over the glass fitter and secure with thumb screws.
- STEP 11. Install the lamp(s). The fixture is rated for 60 watt G lamp.
- DO NOT EXCEED RECOMMENDED WATTAGE!
- STEP 10. Plug cord into a qualified socket of properly rated voltage.
- DIMMING
- CLEANING
- ASSEMBLY AND MOUNTING DIAGRAM
- WIRE NUT/TAPING DIAGRAM
- ,HL111 101G M40
- GENERALITÉ
- INSTALLATION À LA BOÎTE DE DÉRIVATION
- STEP 1. Retirer les fils de la boîte de dérivation et installer la plaque de montage à la boîte de dérivation au moyen des (2) vis de montage.
- INSTALLATION UTILISANT TIGE/FICHE
- STEP 6. Fixer la tige vers le bas de la plaque arrière et faire passer le cordon par la tige.
- STEP 7. Relier le cordon à la tige comme indiqué aux pas 2-4 de l’installation de la boîte à dérivation ci-haut.
- STEP 8. Placer le dispositif à la paroi sur la plaque de montage et sécuriser à l’aide des vis de fixation.
- RÈGLAGE D’INTENSITÉ
- NETTOYAGE
- SCHÉMA D’ASSEMBLAGE ET DE MONTAGE
- SCHÉMA DE BORNE DE RACCORDEMENT ET D’ENVELOPPAGE AVEC RUBAN ISOLANT