Installation Sheet
Table Of Contents
- ,H105603,
- GENERAL
- INSTALLATION
- STEP 1. Pull the wires out from the outlet box, and install mounting plate onto the outlet box using the (2) mounting screws. Strip the Fixture wire ends 5/8”
- STEP 2. Fasten bare ground wire to ground wire from the wall outlet box (usually green or copper color) or connect ground wire to green screw on the mounting plate.
- STEP 3. Connect the neutral (white) fixture wire coming from the fixture base to neutral (usually white) outlet wire. Fasten both wires together with a plastic wire nut and tightly wrap the wire nut with electrical tape.
- STEP 4. Repeat the previous step with the hot (black wires). Make sure there are no exposed wires or strands that could cause a dangerous short circuit.
- FAILURE TO CONNECT THE APPROPRIATE WIRES CORRECTLY COULD RESULT IN SEROIUS INJURY OR DEATH!
- STEP 5. Carefully place connections back into the outlet box
- STEP 6. Place canopy over the mounting plate and secure with Set Screws
- STEP 7. Install the lamp(s). The fixture is rated for 60 watt type A lamp.
- DO NOT EXCEED RECOMMENDED WATTAGE
- STEP 8. Unscrew Screw checker and slide the glass cover up
- STEP 9. Tilt the glass shade slightly and lift up so the glass support is inside the glass. Straighten out the Glass shade and rest on glass support.
- STEP 10. Slide down the glass cover and screw the screw checker back onto the arm.
- STEP 11. Restore power to the circuit at breaker or fusebox.
- DIMMING
- CLEANING
- ASSEMBLY AND MOUNTING DIAGRAM
- WIRE NUT/TAPING DIAGRAM
- ,H105603 M36
- GENERALITÉ
- INSTALLATION
- STEP 1. Pull the wires out from the outlet box, and install mounting plate onto the outlet box using the (2) mounting screws. Strip the Fixture wire ends 5/8”
- STEP 2. Fasten bare ground wire to ground wire from the wall outlet box (usually green or copper color) or connect ground wire to green screw on the mounting plate.
- STEP 3. Connect the neutral (white) fixture wire coming from the fixture base to neutral (usually white) outlet wire. Fasten both wires together with a plastic wire nut and tightly wrap the wire nut with electrical tape.
- STEP 4. Repeat the previous step with the hot (black wires). Make sure there are no exposed wires or strands that could cause a dangerous short circuit.
- FAILURE TO CONNECT THE APPROPRIATE WIRES CORRECTLY COULD RESULT IN SEROIUS INJURY OR DEATH!
- STEP 5. Carefully place connections back into the outlet box
- STEP 6. Place canopy over the mounting plate and secure with Set Screws
- STEP 7. Install the lamp(s). The fixture is rated for 60 watt type A lamp.
- DO NOT EXCEED RECOMMENDED WATTAGE
- STEP 8. Unscrew Screw checker and slide the glass cover up
- STEP 9. Tilt the glass shade slightly and lift up so the glass support is inside the glass. Straighten out the Glass shade and rest on glass support.
- STEP 10. Slide down the glass cover and screw the screw checker back onto the arm.
- STEP 11. Restore power to the circuit at breaker or fusebox.
- RÈGLAGE D’INTENSITÉ
- NETTOYAGE
- SCHÉMA D’ASSEMBLAGE ET DE MONTAGE
- SCHÉMA DE BORNE DE RACCORDEMENT ET D’ENVELOPPAGE AVEC RUBAN ISOLANT
H105603 STELLA
FLUSH MOUNT
www.hudsonvalleylighting.com/mitzi | #mymitzi
SCHÉMA D’ASSEMBLAGE ET DE MONTAGE
OUTLET BOX
CEILING
MO UNTING PLATE
M O UN TIN G SCREWS
GRO UN D SCREW
LAMP
CANO PY
GLASS SUPPO RT
GLASS CO VER
SET SCREWS
GLASS SHADE
SCREW
CHECKER
SCHÉMA DE BORNE DE RACCORDEMENT ET D’ENVELOPPAGE AVEC RUBAN ISOLANT
ELECTRICAL
TAPE
APPROVED
FASTNER
(WIRE NUT)
CACHE-PITON
VIS DE MONTAGE
VIS DE MONTAGE
PLAQUE DE MONTAGE
BOÎTE DE DÉRIVATION
PLAFOND
ABAT-JOUR
EN VERRE
PAVILLON DE VERRE
AMPOULE
SUPPORT DE VERRE
V IS DE MISE À TERRE
VIS À BAGUE
CONNECTEUR APPROVÉ
(BORNE DE RACCORDEMENT)
RUBAN ISOLANT