MODELS: WT-46809 / WS-55809 / WS-55819 / WS-65809 / WS-65819
To set the CRTs white level in the HD mode.
Monchrome pictures have a color tint.
[CRT Circuit]
9. White Balance (HD)
-----
-----
------
-----
HD White Raster
DTV Inputs
1. Supply an HD Full White Raster signal to the DTV Inputs.
2. Select the DTV Inputs (Input button)
3. Activate the Adjustment mode, Video/Chroma Function.
4. Set Item 19 COL to 0.
5. Adjust Items 6 RDRH and 8 BDRH for optimum white at the center of the
screen.
6. Reduce the input signal luminance to 25%.
7. Adjust Items 9 CTRH and 11 CTBH for optimum white.
8. Set the data for Item 19 COL back to 31.
-----
-----
------
------
White Raster (HD&NTSC)
Video & DTV Inputs
[CRT Circuit]
10. Cb, Cr Offset
To set Cb and Cr color signal level.
Incorrect colors.
NTSC Mode
1. Supply an NTSC White Raster (25% luminance) signal to a Video Input.
2. Activate the Adjust Mode, Video/Chroma Function
3. Set Item 19 COL data to 63.
4. Adjust Items 56 CRO1 and 57 CBO1 for optimum white.
5. Set Item 19 COL data to 31.
6. Save data and Exit the Service Mode.
HD MODE
1. Supply an HD White Raster (25% luminance) signal to a Video Input.
2. Activate the Adjust Mode, Video/Chroma Function
3. Set Item 19 COL data to 63.
4. Adjust Items 56 CRO1 and 57 CBO1 for optimum white.
5. Set Item 19 COL data to 31.
6. Save data and Exit the Service Mode.
CIRCUIT ADJUST MODE
Activate …….. MENU-0-1-5-7
Function ...………..AUDIO
Item No. ……….…….VIDEO
Adjust Data .…….ADJUST
Save Data . ………ENTER
Exit …………..MENU (twice)
CIRCUIT ADJUST MODE
Activate …….. MENU-0-1-5-7
Function ...………..AUDIO
Item No. ……….…….VIDEO
Adjust Data .…….ADJUST
Save Data . ………ENTER
Exit …………..MENU (twice)