MODELS: WS-48511 / WS-55511 / WS-55711 / WS-65511 / WS-65611 / WS-65711 / WS-65712 / WS-73711 / WS-B55
To improve edge focus.
Poor focus at the edges of the screen.
[Focus Circuit]
13. Dynamic Focus Preset
-----
-----
------
-----
Monoscope
Video Input
1. Supply a Monoscope signal to a Video Input
2. Activate the Convergence Mode.
3. Select the DF Function under the Conv. Coarse Mode.
4. Set Items 0 DFH and 1 DFV to the data values given in the DF Table.
5. Press 6 to activate CONV-MISC
6. Set 0 FPHS and 1 DPHS to data values given in the CONV-MISC Table.
5. Exit the Conv. Mode.
-----
------
------
-----
Monoscope
Video Input
Poor focus
Note:
This adjustment must be done before Electrostatic Focus. Perform this
adjustment for RED, GREEN, and BLUE monochrome pictures.
1. Supply a VIDEO signal (Monoscope).
2. Cover the Red and Blue Lens (producing a green raster).
3. Adjust the Green Lens for best focus at the center of the Monoscope pattern.
Note:
Attach a white paper to the
screen center. During adjustment,
observe the picture on the screen
from inside for easier adjustment.
4. Repeat Steps 2 and 3 for the Red
and Blue monochrome pictures.
[Video Circuit]
14. Lens Focus
To set the Lens position for optimum focus.
CONVERGENCE MODE
Activate ……..MENU-2-1-5-9
Misc. …………….……"6"
Coarse…………..."5"
Fine ……………………..."4"
Color (R,G or B)……AUDIO
Item No…………...VIDEO
Adjust/Move……….ADJUST
Cursor Toggle...ENTER
Save & Exit..MENU (twice)
DF
(MENU-2-1-5-9-5)
Item Abbr. Data
1 DFH -500
2 DFV -100
CONV MISC
(MENU-2-1-5-9-6)
Item Abbr. Data
9DPHS0
10 DOFS 51