Purpose:
Measuring
Instrument
Test Point
Measuring
Range
Input Signal
Ext. Trigger
Input Terminal
Symptom:
Purpose
Measuring
Instrument
Test Point
Measuring
Range
Input Signal
Ext. Trigger
Input Terminal
Symptom:
MODELS: WS-48511 / WS-55511 / WS-55711 / WS-65511 / WS-65611 / WS-65711 / WS-65712 / WS-73711 / WS-B55
-----
-----
------
------
Monoscope
Video Input
[Video Circuit]
11. Black Level
To set the black level of the picture.
Excess or insufficient brightness.
1. Supply a Monoscope signal to a Video Input.
2. Activate the Adjust Mode, VC Function.
3. Adjust Item 2 SBRT so the 0% and 10% black levels on the gradation scale
are the same.
4. Press ENTER to save data.
7. Exit the Service Mode.
40% 30% 20% 10%
50% 0% 0% 0%
60% 70% 80% 90%
GRADATION SCALE
DC ma meter
DT connector pins 7 & 8
------
-----
Grayscale
RF Input
To set overall beam current to its optimum level.
Excess or insufficient contrast.
Note: Activate the Expand mode (full screen).
1. Supply a Grayscale signal to a RF Input.
2. Activate the Adjust Mode, VC Function.
3. Select Item 1 SCT, signal level automatically reduces.
4. Connect a 3ma DC meter between DT connector pins 7 and 8. Positive lead to
pin 7.
5. Adjust Item 1 SCT to the values given in the Table below.
6. Remove the meter.
7. Save data and Exit the Service Mode.
[Video Circuit]
12. Sub Contrast
CIRCUIT ADJUST MODE
Activate …….. MENU-2-1-5-7
Function ...………..AUDIO
Item No. …….…….VIDEO
Adjust Data .…….ADJUST
Save Data . ……ENTER
Exit …………..MENU (twice)
CIRCUIT ADJUST MODE
Activate …….. MENU-2-1-5-7
Function ...………..AUDIO
Item No. …….…….VIDEO
Adjust Data .…….ADJUST
Save Data . ……ENTER
Exit …………..MENU (twice)
MODEL CURRENT
45 inch models 540 ±5ua
55 inch and 65 inch models 595 ±5ua
73 inch models 620 ±5ua