Service manual

Page 42
Purpose:
Measuring
Instrument
Test Point
Measuring
Range
Input Signal
Ext. Trigger
Input Terminal
Symptom:
Purpose
Measuring
Instrument
Test Point
Measuring
Range
Input Signal
Ext. Trigger
Input Terminal
Symptom:
MODELS: WS-48511 / WS-55511 / WS-55711 / WS-65511 / WS-65611 / WS-65711 / WS-65712 / WS-73711 / WS-B55
To set the CRTs white level in the HD mode.
Monchrome pictures have a color tint.
[CRT Circuit]
9. White Balance (HD)
-----
-----
------
-----
HD White Raster
DTV Inputs
1. Supply an HD Full White Raster signal to the DTV Inputs.
2. Select the DTV Inputs (Input button)
3. Activate the Adjustment mode, VC Function.
4. Set Item 23 COL to 0.
5. Adjust Items 6 RDRH and 8 BDRH for optimum white at the center of the
screen.
6. Reduce the input signal luminance to 25%.
7. Adjust Items 9 CTRH and 11 CTBH for optimum white.
8. Set the data for Item 23 COL back to 31.
-----
-----
------
------
White Raster (HD&NTSC)
Video & DTV Inputs
[CRT Circuit]
10. Cb, Cr Offset
To set Cb and Cr color signal level.
Incorrect colors.
1. Supply an NTSC White Raster (25% luminance) signal to a Video Input.
2. Activate the Adjust Mode, VC Function
3. Set Item 23 COL data to 63.
4. Adjust Items 60 CRO1 and 61 CBO1 for optimum white.
5. Set Item 23 COL data to 31.
6. Save data and Exit the Service Mode.
CIRCUIT ADJUST MODE
Activate …….. MENU-2-1-5-7
Function ...………..AUDIO
Item No. …….…….VIDEO
Adjust Data .…….ADJUST
Save Data . ……ENTER
Exit …………..MENU (twice)
CIRCUIT ADJUST MODE
Activate …….. MENU-2-1-5-7
Function ...………..AUDIO
Item No. …….…….VIDEO
Adjust Data .…….ADJUST
Save Data . ……ENTER
Exit …………..MENU (twice)