Service manual

Page 30
MODELS: WS-48511 / WS-55511 / WS-55711 / WS-65511 / WS-65611 / WS-65711 / WS-65712 / WS-73711 / WS-B55
C. A/V Memory
Each of the external inputs has its own Audio/Video Memory. A change in an A/V setting at a specific input is
stored in memory for that specific input.
A/V Reset
1. The front panel AV Reset button initializes all A/V Memories.
2. The AV Reset in the users menu initializes only the selected inputs A/V Memory.
LED Indicator Diagnostics
The Power ON LED provides an indication of the sets operation, and the possible cause of a malfunction.
1. Initial Control Circuitry Check
Immediately after the TV is connected to an AC power source:
2. Error Code Operational Check
Pressing the front panel INPUT and MENU buttons at the same time, and holding for 5 seconds,
activates the Error Code Mode. The LED flashes denoting a two digit Error Code, or indicating no problem
has occured since the last Initalization.
Note: The front panel buttons must used, NOT those on the Remote Control.
The number of flashes indicates the value of the MSD (tens digit) of the Error Code.
The flashing then pauses for approximately 1/2 second.
The LED then flashes indicating the value of the LSD (ones digit) of the Error Code.
The Error Code is repeated a total of 5 times.
Example: If the Error Code is 24, the LED will flash two times, pause, and then flash four
times.
3. Error Codes
The Error Code designations indicating a malfunction, or no malfunction, are listed below:
Remote Control Operational Modes
There are two Remote Hand Unit Operational Modes, Standard and NetCommand
TM
. The Remote is initially
in in the Standard mode. The NetCommand
TM
mode is used when controlling Home Theater devices using
NetCommand
TM
. To change the Remote Operational Mode:
Set the Remote to the TV Layer
Point the Remote away from the TV.
To change to Netcommand
TM
... Hold the Power button and press 9-3-5 in sequence.
To change to Standard ... Hold the Power button and press 0-0-0 in sequence.
LED Indications Conditions Probable Cause
Off After AC is applied Standy Power Supply or TV µPC not running
Fast Blink for 70 sec. After AC is applied Normal - DM µPC is booting up
Fast Blink (doesn't stop) After AC is applied TV µPC is running, but DM failed to boot up
Slow Blink Set is Off Normal - Timer is set for Automatic Turn ON
Error Code Probable Cause
12 Normal Operation - No Error Detected
21 X-Ray Protect
22 Short Protect
23 Loss of Horizontal Deflection
24 Loss of Vertical Deflection