Service manual
6
Indoor model MSZ-GE42VA MSZ-GE42VAD MSZ-GE50VA MSZ-GE50VA2 MSZ-GE50VAD
Power supply Single phase 230 V, 50 Hz
Electrical
data
Power input
1
Cooling
W
29 43
Heating 30 39
Running
current
1
Cooling
A
0.29 0.39
Heating 0.31 0.36
Fan
motor
Model RC0J40-FK
Current 1
Cooling
A
0.29 0.39
Heating 0.31 0.36
Dimensions W × H × D mm 798 × 295 × 232
Weight kg 10
Special remarks
Air direction 5
Airfl ow
Cooling
Super High
-
+ LONG + POWERFUL
Super High
m
3
/h
768 906
High 624 714
Med. 516 576
Low 408 468
Quiet 348
390(420 2)
Heating
Super High
-
+ LONG + POWERFUL
Super High
m
3
/h
786 870
High 624 732
(612
2)
Med. 516 576
(540
2)
Low 420 468
Quiet 348 390
Sound level
Cooling
Super High
-
+ LONG + POWERFUL
Super High
dB (A)
46 49
High 40 44
Med. 35 38
Low 30 33
Quiet 26 28
Heating
Super High
-
+ LONG + POWERFUL
Super High
dB (A)
46 48
High 40 43
Med. 35 37
Low 30 33
Quiet 26 28
Fan speed
Cooling
Super High
-
+ LONG + POWERFUL
Super High
rpm
1,120 1,280
High 950 1,060
Med. 810 890
Low 680 750
Quiet 600
650 (690
2)
Heating
Super High
-
+ LONG + POWERFUL
Super High
rpm
1,140 1,240
High
950 (930
2) 1,080(930 2)
Med. 810
890 (840 2)
Low 690 750
Quiet 600 650
Fan speed regulator 5
Remote controller model KM09A
NOTE: Test conditions are based on AS/NZS 3823.1.1.
Cooling: Indoor Dry-bulb temperature 27°C Wet-bulb temperature 19°C
Outdoor Dry-bulb temperature 35°C Wet-bulb temperature (24°C)
Heating: Indoor Dry-bulb temperature 20°C Wet-bulb temperature 15.5°C
Outdoor Dry-bulb temperature 7°C Wet-bulb temperature 6°C
1 Measured under rated operating frequency. 2 For multi system.
OBH531E