Specifications
Special Primary Voltage/Current and Special Secondary Voltage are settable
With the password function, the following items can be protected from an accidental execution.
Periodic Monitoring Function
No.
1
2
3
4
shift to the setting mode
Reset the max./min. values
Reset the value of active energy, reactive energy and apparent energy
Reset the value of periodic active energy
Adjust the time limit of rolling demand
Reset the peak value of rolling demand
Reset the value of operating time
Password-protected item
No.
5
6
7
Password-protected item
(1) Special primary current (2) Special primary voltage
60V~75kV
Under 100V: Top two digits setting
Over 100V: Top three digits setting
1A~30kA
Under 10A: Top two digits setting
Over 10A: Top three digits setting
Three phase 4-wire system
63.5, 100, 110, 115 and 120V
Three phase 3-wire, Single phase 2-wire system
100, 110 and 220V
(3) Special secondary voltage
Power consumption can be measured in two individual intervals (e.g., peak/off-
peak, day/night, etc.).
The time segments can be switched according to the setting via communication
or the digital input (DI).
(The time segments cannot be switched manually (button operation).)
Rolling Demand Function
Rolling demand is the estimated power consumption in a specified period (interval).
There are two way calculation of rolling demand.
Power consumption
(period 1)
Power consumption
(period 2)
qRolling block
Use rolling block to set the interval and sub-intervals from
1~60min (1min intervals). Rolling demand is calculated and
updated at the end of each sub-interval.
wFixed block
Use fixed block to set the interval from 1~60min (1min
intervals). Rolling demand is calculated and updated at the
end of each interval. (For fixed block, use the same time
limits both of interval and sub-interval).
<Rolling demand calculation>
Rolling demand is calculated when
the sub-interval has been
completed.
<Rolling demand display>
When an interval has been completed,
the rolling demand displayed is the
newest time limit value.
<Rolling demand calculation>
Rolling demand is calculated
when the sub-interval has been
completed.
<Rolling demand display>
When an interval has been completed,
the rolling demand displayed is the
newest time limit value.
Time (min)
0 5 10 15
15min
5min
20 25
Time (min)
0 15 30
<Example: Interval, 15min; Sub-interval, 5min>
<Example: Interval, 15min; Sub-interval, 15min>
15min 15min
Output terminalStatus
Alarm
No alarm
Display
ON
OFF
Open
Closed
qDisplay
»The same as for the operating mode, display patterns and other data are shown as set.
»Both maximum and minimum values can be displayed.
wCommunication data
»Communication items and value are the same one on the display. The items value that are
not displayed is 0 (zero).
»Measuring items set for alarm will be displayed at the time of an alarm.
»Input/Output contact status can be monitored.
(1) Communications Test
qDisplays current alarm and contact status.
wPress the Reset button for 2sec, and regardless if there is an alarm or not,
the display and contact output will operate as follows.
(2) Alarm/Contact Output Operation Test
qDisplay the output items.
wPress the
+
or
-
button to change the
analog output.
Note: Default value is 0%.
(3) Analog Output Operation Test
Press the Reset button one time to output one pulse.
Note: After reaching 50, count will return to 1.
(4) Pulse Output Operation Test
Test Function
»Even during a setup of a facility, where no current/voltage input is found, analog output, pulse output, alarm output, contact output,
and communication data is replied. This allows for checkup of wiring and monitoring program system.
*Depending on the optional unit and settings, the test function may not be available (may not be displayed).
Standards
All products are compliant with CE Marking, UL Standards, KC mark and FCC/IC.
0%
25%
4mA
8mA
Output
4-20mA
Output specs
50% 12mA
75% 16mA
100% 20mA
0%
25%
50%
75%
100%
0 1 2
…
49 50[pulse]
Note: Default value is 0 pulses.
ME96 Super-S Series Features
Variety of Complementary Features
Password Function
7 8