Specifications

Related Products
Safety Precautions
EcoWebServerIII
ME110SS
EcoMonitorLight
To ensure safety, read the following items carefully before use and always comply with procedures during use. Special attention should be given
to items enclosed in a box and marked “Caution.” Additionally, please carefully read the operations manual supplied with the product before use,
and ensure that the manual read by the end user as well.
1
Usage Environment and Conditions
Do not use these products under any of the following conditions. Doing so may cause erroneous operation and/or reduced service life.
Ambient temperature is outside the range of -5~55°C
Daily average temperature over 35°C
Relative humidity over 85% or presence of condensation
Presence of excessive dust, corrosive gas, salt or oil/smoke
Product is subject to excessive vibration or shock
Product is in direct contact with rain, water drops or sunlight
Altitude is above 2,000m
Excessive external noise
Pollution level is 2 or higher
Transient overvoltage is 4,000V or higher
Presence of metal fragments or conducting substances
2
Installation
Please note the following items regarding installation. To ensure safety, installation is to be performed by a qualified technical electrician.
Affix the main unit to the panel before use
The LCD display contrast changes depending on the angle from which it is viewed. Install it in a position that ensures a suitable angle of view.
Tighten screws using a torque of approx. 0.3~0.5N·m
To prevent damage to the LCD, take care not to subject the LCD/front of the main unit to shock/impact.
3
Connections
See pages 26~28 of this catalog for information regarding connections.
4
Preparations Before Use
Before use, perform settings such as the VT primary voltage, CT primary current, power scale and demand time limit in accordance with the operations manual
supplied with the product; setting errors may cause incorrect measurement/operation.
5
Usage Procedures
Use the products within the rated range. Using the products outside the rated range may cause erroneous operation or product malfunction.
Do not use the products for special applications such as nuclear power, aerospace or medical devices/systems.
6
Repairing at Time of Malfunction/Error
If a product listed in this catalog malfunctions, read the troubleshooting section of the operations manual (detailed version) and confirm the symptoms. If the problem
is not listed, please contact a Mitsubishi Electric representative.
7
Maintenance/Inspections
Wipe away any dust/dirt on the surface of the product with a soft cloth.
Do not leave chemical cloths, etc. in contact with the product for long periods, and avoid the use of benzene, thinner, etc. when wiping the product surface. Doing so
may cause deformation or cause the coating to peel away.
To ensure correct use for the full service life of the product, please perform the following inspections:
qCheck for damage to the product wCheck for display malfunctions (e.g., does not respond to input) eCheck for loose installation or terminal block wire connections
(check regularly once every six months/year) always making sure that power has been turned off beforehand). rCheck for unusual smell, noise or rise in temperature.
8
Storage
Do not store the product for long periods of time under any of the following conditions. Doing so may lead to a malfunction or reduced service life.
Ambient temperature outside the range of -25~+75°C Daily average temperature of more than 35°C Relative humidity exceeding 85% or condensation present
Excessive dust, corrosive gas, salt or oil/smoke present Product is subject to excessive vibration or shock Product is in direct contact with rain, water drops or sunlight
9
Disposal
These products do not use nickel-cadmium batteries. Dispose of them as industrial waste.
10
Warranty Period
The warranty period for the products in this catalog expires one year from the date of purchase or one year and six months after the date of manufacture;
whichever is earliest. Even during the warranty period, the warranty shall not apply to malfunctions attributable to intentional negligence or erroneous use by
the customer, and the fee for any repair required as the result of such negligence shall be the liability of the customer.
Mitsubishi Electric shall not be liable for: Damage that cannot be attributed to Mitsubishi Electric; lost opportunity or earnings resulting from failure of a
Mitsubishi Electric product; damage, secondary damage or compensation for an accident resulting from special circumstances regardless of whether or not
the circumstances were foreseeable; or damage to products or other services for products not manufactured by Mitsubishi Electric.
11
Product Exchange Cycle
Although it depends on usage conditions, as a guide, it is recommended that the products listed in this catalog be renewed after 10 years.
To ensure safety, connections are to be performed by an electrical engineer qualified in wiring.
Check connection diagrams carefully before performing connections. Incorrect connections may result in VT burnout caused by a VT secondary-side short
circuit or high voltage on the CT secondary side, which may lead to device malfunction, fire or electrical shock.
Do not work with live wires; there is a risk of electric shock and exposure to high voltage due to short-circuiting or CT secondary side opening, which may lead
to malfunction, fire or electrical shock.
Use electrical wire sizes compatible with the rated current. Use of unsuitable sizes may cause heat generation, which may lead to a fire.
After performing connections, check that no connections have been missed. Missed connections may result in erroneous operation or high voltage on the CT
secondary side, which may lead to a fire or electrical shock.
Do not make any modifications to the products. Using products after modification may cause a malfunction, electrical shock or fire.
AC100~240V (±15%) 50-60Hz
DC100~240V (−30%, +15%)
3-phase, 4-wire: Max. 277/480VAC
3-phase, 3-wire: Delta connection: Max. 220VAC, Star connection: Max. 440VAC
1-phase, 3-wire: Max. 220/440VAC
1-phase, 2-wire: Delta connection: Max. 220VAC, Star connection: Max. 440VAC
5A/1A
Auxiliary power
supply
Instrument
ratings
Current
Voltage
50-60Hz (dual use)
Frequency
Auxiliary power supply and instrument ratings
Mitsubishi Electric Energy-saving Data Collection Server
Simple Set-up
When using the set-up software supplied, power management meters
connected to CC-Link and measurement data can be set by mouse and
keyboard operations.
Display Measurement Data as Graphs on a Web Browser
The main unit has a built-in web server that allows anyone, anywhere to
understand the amount of energy being used in real time via computer
without requiring additional software, thereby supporting early detection of
energy waste.
Automatic Transmission of Data Collected, Mail Notifications and
Contact Output
Users are notified of changes in energy, facilities, etc. via e-mail and alarms.
Energy management targets and status monitoring of entire factories and
buildings help ensure that problems onsite are detected without fail.
PLC data can also be sent to EcoWebServerIII by Ethernet.
Utilize an internal network to show the data of numerous company sites at
a centralized location (e.g., head office).
Common-use Models
Two phase wiring system (Three phase 3-wire and Three phase 4-wire
systems) were required previously, but user needs can now be met with a
single unit.
Enhanced Visibility
Wide-angle-view LCD with top and bottom tiers integrated for total freedom in
installation. Crystal-clear display makes text even easier to read when
viewed from the front.
Operating Time, CO
2
Conversion, Alarm Display Functions
Functions that enable load operating time measurement, conversion to CO
2
emissions and backlight blinking at the time of an alarm are incorporated.
Simple Measurements
The built-in LCD enables easy setting, measurement and display of power
used for energy management.
MODBUS
®
RTU (RS-485) Communication as Standard Equipment
Meters come with MODBUS
®
RTU communication as standard equipment,
allowing the device to be used as a PLC system, other high-order system,
display device (GOT), etc.
Logging/Communication Units for Expanded Measurement
Applications
The product line-up also includes logging units/communication units (CC-Link
communication unit) that can be incorporated as add-on options, enabling
installations that best match to the customer’s usage environment.
Logging unit: Data measured by the main unit (current, voltage, power,
etc.) can be output to an SD memory card in CSV file format, realizing
simple data management.
Highly Accurate Measurements and Support Functions
Customer activities are supported through functions such as 250µs
high-precision (short-cycle load) measurement, operating time measurement,
wiring error detection and test output.
ME110 Super-S Series Electronic Multi-measuring Instruments
The innovative design of the SS Series is supporting the realization of energy-saving
measurement monitoring systems that are easy to use and read
Energy Measuring Unit
Easily accessible “energy visualization” with a single unit!
A two-model line-up: a Three phase 3-wire system designed for users wanting simple power measurements at low cost; and a Three phase 4-wire
system designed for users looking for basic power measurements plus something extra (harmonic measurements, alarm monitoring, etc.).
Simplify data management with
EcoWebServer III!
LAN (Ethernet)
CAUTION
CAUTION
29 30