Specifications
Operating Instructions
Lead Status
Lag status
Scale of the bar graph
Outside range
Alarm indicator
Bar graph status
Phase status
Digital
Unit
Metering status
Harmonics
Setup status
Test status
Clock status
Alarm status
Communication status
Power factor status is lead
Power factor status is lag
The scale of the bar graph
Measurement value is outside range of scale of the bar graph
The setting value of the upper or lower limit
The item expressed with the bar graph
The phase for each of the digital displays
The measured value is displayed in a digital number
The unit for each of the digital display
When it is blinking, the instrument is counting active energy
The digital displays are harmonics values
Setup mode
Test mode
When it is blinking, the instrument is counting operating time
The upper or lower limit value was exceeded
The instrument is equipped with communication function
NO.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
■Functions
»LCD Functions
●Basic Set-up Operations
(1) In the case of Three phase 4-wire setting (ME96SSH-MB)
Set-up menu 1: Basic settings (set phase wire system, display pattern, Using VT/direct input, CT primary current, etc.)
■Set-up
»Set-up workflow (in the case of ME96SSH-MB)
»Button Functions
Segment name Description
For correct measurement, it is necessary to set the primary voltage/current in set-up mode. Access set-up mode from the measurement
mode and set the necessary items. Factory default settings will apply to items not set.
To access setting mode, press and hold the and buttons down at the same time
for 2s. Press the button to display the items to be set, and the and buttons to set
the details. Settings can be saved for each set-up menu No. To do so, press the button
when the End screen is displayed.
SET
SET
RESET
SET
(2) In the case of settings other than Three phase 4-wire (ME96SSH-MB)
Additional screens
Notes 1. Basic measurements are possible by adjusting settings in menu 1
( area enclosed by dotted line).
Notes 2. Item settings vary depending on the model.
Notes 3. Setting confirmation menu 9 (test mode) is not displayed in the setting mode.
Set-up menu
qPhase/Wire system
wDisplay pattern
eVT/Direct voltage
DISPLAY
SET
DISPLAY
SET
DISPLAY
SET
DISPLAY
SET
Adjust the set-up menu No. to “1”
qSet the phase/wire system according to the number
of measurement circuits targeted
wSet the display pattern
○: Can be displayed with this setting only
△: Other settings are required to display data
□: Select P00 and set display order and position
3P4: 3-phase, 4-wire system
3P3, 2Ct: 3-phase, 3-wire system (2CT)
3P3, 3Ct: 3-phase, 3-wire system (3CT)
1P3, 1n2: 1-phase, 3-wire system (1N2 display)
1P3, 1n3: 1-phase, 3-wire system (1N3 display)
1P2: 1-phase, 2-wire system
eSet VT
In the case of direct measurements (without VT) ⇒ To select no, press and see (1) below.
In the case of using VT ⇒ To select yes, press and see (2) below.
・To set Three phase 4-wire
・
To set Three phase 3-wire or Single phase 2-wire
(1) In the case of direct measurements (without VT)
(a) Three phase 4-wire setting (phase voltage/line voltage)
(b) Three phase 3-wire (2CT, 3CT) or Single phase 2-wire setting (line voltage)
(c) Single phase 3-wire setting (1N2, 1N3) (phase voltage/line voltage)
SET
SET
63.5/110V 100/173V 110/190V 220/380V 240/415V 254/440V 277/480V
no yES
yES no
110V 220V 440V
110/220V 220/440V
<For Single phase 3-wire setting for qPhase/Wire system >
Only used for direct measurements.
Skipped for this setting.
The underlined setting parameter are
the initial value.
Set-up menu End
Measurement screen
Phase/
Wire
Display
pattern
Using VT/
direct input
CT current
Frequency
Rolling demand
time limit
Demand current
time limit
Set-up menu 1
Current
scale
Voltage
scale
Power
scale
Reactive
power scale
Power factor
scale
Power used
scale
Harmonic
display
Set-up menu 3
Function
display
Version
display
Backlight
brightness
Backlight
connection/
automatic
Display
refresh time
Set-up menu 4
Upper/Lower
limit alarm
items
Upper/Lower
limit alarm
values
Alarm
mask time
Alarm reset
method
Backlight
flashes at time
of alarm
Motor starting
current mask
function
Pulse/Alarm
output function
Pulse
output
Set-up menu 5
Analog
output 1
Analog
output 2
Analog
output 3
Analog
output 4
Output
limit
Set-up menu 6
Time-based
power used
display
Time-based
power used
toggle setting
Rolling
demand
display
Rolling demand
time limit
adjustment setting
Contact
input/output
display
Contact
input reset
method
Set-up menu 7
Operating
time display
Test mode
Operating
time count
target
Operating
time threshold
value
Phase display
setting
IEC mode
setting
Set-up menu 8
Setting value confirmation menu 9
End
display
Cancel
display
Change/
Confirm
values set
Enter
set-up
mode
Enter setting value
confirmation mode
MODBUS
®
RTU
address
Communication
type
MODBUS
®
RTU
baud rate
MODBUS
®
RTU
parity
MODBUS
®
RTU
stop bit
Set-up menu 2
CC-Link
station No.
CC-Link
baud rate
CC-Link
version setting
CC-Link
reset
<When ME-0040C-SS96 is attached>
w
e
e(1)
q
Operation (function) details
Access set-up mode from operating mode
Access setting value confirmation
mode from operating mode
Save settings and return to operating mode
Select set-up menu
Move to next screen
Return to previous setting item
Skip remaining settings
Select cancel
Button operation
Press for 2s
Press for 2s
Press for 1s
Symbol
+
or
or
DISPLAY
SET
SET
RESET
SET
SET
SET
Functions
Button Functions
Basic functions
Button
Set up setting items such as primary voltage and
current, and choose and indicate setting itmes
Change setting and bar graph display
Change display from Max/Min to instantaneous value
Change phase
Change display
Push for 2s
Push for 2s
Push for 2s
Push for 2s
Push for 1s
Manual display change ⇔ Cyclic display change
Manual phase change
⇔
Cyclic phase change
Zoom display of Wh, varh etc
Reset all the Max/Min values
Fast forward or fast return values when setting
Reset Wh, varh, Vah values to zero by
hoiding down the buttons for 2 sec
or
MAX/MIN
PHASE
DISPLAY
DISPLAY
PHASE
RESET
SET
RESET PHASE
+
or
+ +
+
SET
Special functions
P01
P02
P03
P04
P05
P06
P07
P08
P09
P10
P11
P12
P13
P00
○
○
○
○
○
○
○
○
○
○
○
○
□
○
○
○
○
○
○
○
○
○
○
○
○
□
○
○
○
○
□
○
○
○
○
□
○
○
○
○
○
○
○
○
○
○
○
○
□
○
○
○
○
○
○
○
○
○
○
□
○
○
○
○
○
○
□
○
○
○
○
□
○
○
○
○
□
○
○
○
○
□
○
○
○
○
○
○
□
○
○
□
○
○
□
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
A
A
AN DA
DA V W PF var Hz
Wh
(Imported)
Wh
(Exported)
Varh
(Imported lag)
Wh
(Imported)
Wh
(Exported)
varh
Wh
(periodic)
DW
V W PF var VA VahHz
Wh
(Imported)
Wh
(Exported)
Wh
(Imported)
Wh
(Exported)
varh
vah
Wh
(periodic)
HI/HV DI/DO
DW
Operating time
HI/HV DI/DO
Operating time
Varh
(Imported lag)
DAN
Display pattern
Display pattern
□
○
○
○
○
○
○
△
○
○
△
P01
P02
P03
P04
P05
P06
P07
P08
P09
P10
P11
P12
P13
P00
○
○
○
○
○
○
○
○
○
○
○
○
□
○
○
○
○
□
○
○
○
○
○
○
○
○
○
○
○
○
□
○
○
○
○
○
○
○
○
○
○
□
○
○
○
○
○
○
□
○
○
○
○
□
○
○
○
○
□
○
○
○
○
○
○
□
○
○
□
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
△
□
○
○
○
○
○
○
△
Additional screens
1 2
3
4
5
9
10
4
6
7
8
12 13 14 15 16 11
3
13 14