Specifications

-
4
-
Model SRK40HG-S (Indoor unit)
SRC40HG-S (Outdoor unit)
Item
Model
SRK40HG-S SRC40HG-S
Cooling capacity
(1)
W 3600
Heating capacity
(1)
W 3920
Power source 1 Phase, 220/230/240V, 50Hz
Cooling input kW 1.12
Running current (Cooling) A 5.3/5.2/5.1
Heating input kW 1.15
Running current (Heating) A 5.4/5.3/5.2
Inrush current A 25.2
COP Cooling: 3.21 Heating: 3.41
Cooling
Sound level Hi: 40, Me: 38, Lo: 34 49
Noise level
Power level
dB
56 63
Heating
Sound level Hi: 40, Me: 38, Lo: 34 52
Power level 57 66
Exterior dimensions
Height × Width × Depth
mm
268 × 790 × 199 540 × 780 × 290
Color Fine snow Stucco white
Net weight kg 8.5 38
Refrigerant equipment
Compressor type & Q’ty
5KS150DBQ01 (Rotary type) × 1
Motor kW 1.1
Starting method Line starting
Heat exchanger Louver fins & inner grooved tubing Straight fin & inner grooved tubing
Refrigerant control Capillary tubes + Electronic expansion valve
Refrigerant
(3)
kg R410A 1.15 (Pre-Charged up to the piping length of 15m)
Refrigerant oil R 0.43 (RB68A or Freol Alpha 68M)
Deice control Microcomputer control
Air handling equipment
Fan type & Q’ty
Tangential fan × 1 Propeller fan × 1
Motor W 14 22
(Cooling) 9.0 32
Air flow (at High)
(Heating)
CMM
10.0 32
Air filter, Q’ty
Polypropylene net (washable)
×
2
Shock & vibration absorber Cushion rubber (for compressor)
Electric heater ––
Operation control
Operation switch
Wireless-Remote control
Room temperature control Microcomputer thermostat
Pilot lamp RUN (Green), TIMER (Yellow), HI POWER (Green), ECONO (Orange)
Safety equipment
O.D mm (in) Liquid line: φ6.35 (1/4) Gas line: φ12.7 (1/2)
Connecting method Flare connecting
Attached length of piping Liquid line: 0.4 m
Gas line : 0.33 m
Insulation Necessary (Both sides)
Drain hose Connectable
Power source cord 2 m (3 cores with Earth)
Size × Core number 1.5 mm
2
× 4 cores (Including earth cable)
Connection wiring
Connecting method Terminal block (Screw fixing type)
Accessories (included)
Mounting kit, Clean filter (Natural enzyme filter × 1, Photocatalytic washable deodorizing filter × 1)
Optional parts
Notes (1) The data are measured at the following conditions.
Item Indoor air temperature Outdoor air temperature
Standards
Operation DB WB DB WB
Cooling 27ºC 19ºC 35ºC 24ºC ISO-T1, JIS C9612
Heating 20ºC 7ºC 6ºC ISO-T1, JIS C9612
(2) The operation data are applied to the 220/230/240V districts respectively.
(3) The refrigerant quantity to be charged includes the refrigerant in 15 m connecting piping.
(Purging is not required even for the short piping.)
Operation data
(1)
Refrigerant
piping
The piping length is 7.5 m.
(220/230/240V)
Frost protection, Serial signal error protection, Compressor overheat protection,
High pressure control, Indoor fan motor error protection