Specifications
408
FDEN-H
(2) This packaged air-conditioner is manufactured and tested in conformity with the following standard. JIS B8616 “UNITARY AIR-CONDITIONERS”
(3) The operation data indicate when the air-conditioner is operated at 220/240V 50Hz.
(4) Indicates the value at mild mode .
Notes (1) The data are measured at the following conditions.
Item Indoor air temperature Outdoor air temperature
Standards
Operation DB WB DB WB
Cooling 27˚C 19˚C 35˚C 24˚C
Heating 20˚C – 7˚C 6˚C
ISO-T1, JIS B8616
Operation data
(3)
Item
Model
FDEN208H FDC208HEN3A
Nominal cooling capacity
(1)
W 5000
Nominal heating capacity
(1)
W 5400
Power source 1 Phase, 220/240V, 50Hz
Cooling input kW 1.77/1.86
Running current (Cooling) A 8.2/8.0
Power factor (Cooling) % 98/97
Heating input kW 1.73/1.83
Running current (Heating) A 8.0/7.8
Power factor (Heating) % 98/98
Inrush current (L.R.A) A 44
Noise level
(4)
dB(A) Hi: 43 Lo: 38 52
Exterior dimensions
mm 184× 1000 × 650 690 × 880 × 290
Height × Width × Depth
Net weight kg 22 49
Refrigerant equipment
– RM5523GNE4 × 1
Compressor type & Q’ty
Motor kW – 1.7
Starting method – Line starting
Heat exchanger Louver fines & inner grooved tubing Slitted fines & bare tubing
Refrigerant control Capillary tube
Refrigerant R22
Quantity kg Holding charged
0.98 [Pre-charged up to the piping length of 0m]
Refrigerant oil r – 0.7 (BARREL FREEZE 32SAM)
Defrost control MC controlled de-icer
High pressure control High pressure switch
Air handling equipment
Fan type & Q’ty
Multiblade centrifugal fan × 2 Propeller fan × 1
Motor W40 × 155 × 1
Starting method Line starting Line starting
Air flow (Standard) CMM Hi:14 Lo:10 56
Fresh air intake Unavailable –
Air filter, Q’ty Polypropylene net × 2 (washable) –
Shock & vibration absorber Rubber sleeve (for fan motor) Rubber mount (for compressor)
Electric heater W – 20 (Crank case heater)
Operation control
Operation switch Wireless remote control switch – (Indoor unit side)
Room temperature control Thermostat by electronics –
Safety equipment Internal thermostat for fan motor. Internal thermostat for fan motor.
Frost protection thermostat. Abnormal discharge temperature protection
Installation data mm
Liquid line: φ6.35 (1/4″) Gas line: φ15.88 (5/8″)
Refrigerant piping size (in)
Connecting method Flare piping
Drain hose (Connectable with VP20) –
Insulation for piping Necessary (both Liquid & Gas lines)
Accessories Mounting kit. Wireless remote controller
Optional parts –
FDEN208HEN-S1
10.2 SELECTION DATA
10.2.1 Specifications
(1) Refrigerant R22 use models
Model FDEN208HEN-S1