Specifications

24
SRK-GZ
OFF
ON
OFF
0
34
36
25 : 48
35 : 50
Operating pattern
D range C range B range A range
Inverter frequency
Indoor fan
Outdoor fan
Determination of cooling
oriented dehumidifying
operation range
4th speed
2nd speed
1st speed
Temperature check
3 min. 3 min. 3 min. 3 min.
20 sec.
(b) Outline of control
(i) Cooling oriented dehumidifying
Room temperature is checked at 3-minute intervals after selecting the cooling or heating oriented dehumidifying in
order to determine the operation range.
Operation range
D C B A
Low –1 0 +2 Hight
Room temperature – Setting temperature (deg)
S SRK25, 35GZ-L1
-1 0
Room temperature - Setting temperature (deg.)
+2 HighLow
55
70
100
Operation range
Relative humidity (%)
I
C B A
F E D
55 70
Relative humidity (%)
Humidity sensor setting range
High-humidity range (A, B, C, I)
Low-humidity range (D, E, F, I)
Operating pattern
Inverter frequency
(rps)
Indoor fan
7 speed
6 speed
5 speed
4 speed
3 speed
2 speed
1 speed
OFF
2 speed
OFF
Outdoor fan
Determination of cooling
oriented dehumidifying
operation range
60
3 min. 3 min. 3 min. 3 min. 3 min. 3 min. 3 min.
20 sec.
40
14
60
40
14
0
Temperature and humidity check
Temperature and humidity are checked at 3-minute intervals after selecting the cooling or heating oriented dehumidify-
ing in order to determine the operation range.
S SRK502Z-L
A range B range C range D range E range F range I range