Specifications

23
SRK-GZ
Model SRK25GZ-L1 SRK35GZ-L1 SRK502Z-L
1 cycle 1 cycle 1 cycle
Item 2 min. 3 min. 2 min. 3 min. 2 min. 3 min.
Inverter frequency 92Hz 102Hz 108rps
Indoor fan 5th speed 6th speed 6th speed 7th speed 6th speed 7th speed
Outdoor fan ON ON Me
(b) Detail of control in each mode (Pattern)
(i) Fuzzy operation
During the fuzzy operation, the air flow and the inverter frequency are controlled by calculating the difference between
the room temperature setting correction temperature and the suction air temperature.
(ii) Cooling thermostat operation
1) Operating conditions
During the cooling fuzzy operation or when the frequency obtained by the fuzzy calculation is less than -24 Hz.
2) Detail of operation
(iv) Cooling HI POWER operation (HI POWER button on remote controller: ON)
The unit is operated continuously for 15 minutes regardless of the setting temperature.
1) Detail of operation: Following cycle is repeated 3 times.
(iii) Continuous mode operation (Temperature setting button on remote controller: Continuous)
(6) Outline of cooling operation
(a) Air capacity selection
(i) Frequency of inverter changes within the range of selected air flow.
Model
Air flow selection
SRK25GZ-L1 SRK35GZ-L1 SRK502Z-L
AUTO Frequency 34~92Hz 34~102Hz 18~118rps
Air flow Depends on frequency.
HI Frequency 34~92Hz 34~102Hz 18~118rps
Air flow 5/6th speed 5/6th speed 5~7th speed
MED Frequency 34~68Hz 34~86Hz 18~92rps
Air flow 4th speed fixed 4/5th speed 4/5th speed
LO Frequency 34~44Hz 34~44Hz 18~44rps
Air flow 3/4th speed 3rd speed 3/4th speed
(ii) When any protective function actuates, the operation is performed in the mode corresponding to the function.
(iii) Outdoor blower is operated in accordance with the frequency.
Inverter frequency 0Hz [Comp. stopped]
Indoor fan Corresponds to fan speed switch.
Outdoor fan Stop
Model SRK25GZ-L1 SRK35GZ-L1 SRK502Z-L
Item AUTO HI MED LO AUTO HI MED LO AUTO HI MED LO
Inverter frequency 82Hz 68Hz 44Hz 86Hz 52Hz 140rps 90rps 46rps
Indoor fan 5th speed 4th speed 5th speed 3rd speed 8th speed 6th speed 4th speed
Outdoor fan ON ON 5th speed 3rd speed 2nd speed
Notes (1) In the continuous mode, the unit is operated with the continuous cooling operation without adjustment of room temperature.
(2) Protective functions will actuate with priority even during the continuous mode operation.
Notes (1) Protective functions will actuate with priority even during the “HI POWER” operation.
(2) Room temperature is not adjusted during the “HI POWER” operation
(3) “HI POWER” operation is prohibited during the operation controlled with the pleasant reservation timer.
Heating oriented dehumidifying Cooling oriented dehumidifying
Low –3 High
Room temperature - Setting temperature (deg)
Cooling or heating oriented dehumidifying is selected again one hour after the first selection of the cooling or heating oriented dehumidifying.
(7) Outline of dehumidifying operation
(a) After operating the indoor blower for 20 seconds from immediately after the start of operation, the indoor temperature is
checked and, based on the result of check, the cooling oriented dehumidifying or heating oriented dehumidifying is selected.