Specifications

-
4
-
Model SRK40HD-S (Indoor unit)
SRC40HD-S (Outdoor unit)
Item
Model
SRK40HD-S SRC40HD-S
Cooling capacity
(1)
W 3600
Heating capacity
(1)
W 4000
Power source 1 Phase, 220/230/240V, 50Hz
Cooling input kW 1.12
Running current (Cooling) A 5.3/5.1/4.9
Heating input kW 1.16
Running current (Heating) A 5.5/5.3/5.1
Inrush current A 25.2
COP Cooling: 3.21 Heating: 3.42
Cooling
sound level Hi 40, Me 38, Lo 34 49
Noise level
Power level
dB
56 63
Heating
sound level Hi 41, Me 38, Lo 34 50
Power level 57 64
Exterior dimensions
Height × Width × Depth
mm
250 × 815 × 249 640 × 850 × 290
Color Cool white Stucco white
Net weight kg 9.0 41
Refrigerant equipment
Compressor type & Qty
5KS150DBB [Rotary type] × 1
Motor kW 1.1
Starting method Line starting
Heat exchanger Louver fins & inner grooved tubing
Refrigerant control Capillary tubes + Electronic expansion valve
Refrigerant
(3)
kg R410A 1.17 (Pre-Charged up to the piping length of 15m)
Refrigerant oil R 0.43 (RB68A)
Deice control MC control
Air handling equipment
Fan type & Qty
Tangential fan × 1 Propeller fan × 1
Motor W 14 35
(Cooling) 9.0 38
Air flow (at High)
(Heating)
CMM
9.5 38
Air filter, Qty
Polypropylene net (washable)
×
2
Shock & vibration absorber Cushion rubber (for compressor)
Electric heater ––
Operation control
Operation switch
Wireless-Remote controller
Room temperature control MC. Thermostat
Pilot lamp RUN (Green), TIMER (Yellow), HI POWER (Green), ECONO (Orange)
Safety equipment
O.D mm (in) Liquid line: φ6.35 (1/4) Gas line: φ12.7 (1/2)
Connecting method Flare connecting
Attached length of piping Liquid line: 0.4 m
Gas line : 0.33 m
Insulation Necessary (Both sides)
Drain hose Connectable
Power source cord 2.5 m (3 cores with Earth)
Size × Core number 1.5 mm
2
× 4 cores (Including earth cable)
Connection wiring
Connecting method Terminal block (Screw fixing type)
Accessories (included) Mounting kit
Optional parts
Notes (1) The data are measured at the following conditions.
Item Indoor air temperature Outdoor air temperature
Standards
Operation DB WB DB WB
Cooling 27ºC19ºC35ºC24ºC ISO-T1, JIS C9612
Heating 20ºC 7ºC6ºC ISO-T1, JIS C9612
(2) The operation data are applied to the 220/230/240V districts respectively.
(3) The refrigerant quantity to be charged includes the refrigerant in 15 m connecting piping.
(Purging is not required even in the short piping.)
Operation data
(1)
Refrigerant
piping
Compressor: Overheat protection, overcurrent protection, Serial signal error protection, Indoor fan
motor error protection, Frost protection
The piping length is 7.5m.