Specifications

-
72
-
Stops for approximately
5 seconds in the
horizontal position.
(2) Flap control
Control the flap by AIRFLOW button on the wireless remote controller.
(a) Natural flow (AUTO)
The flap will be automatically set to the angle of air flow best to operation.
(i) Starting time of operation
s
In case of cooling
t
and dry operation
ON/OFF
Back-up switch
(c) Swing flap
Flap moves in upward and downward directions continuously.
(ii) When not operating
The flap returns to the position of air flow directly below, when operation has stopped.
(b) Memory flap
While the flap is operating if the AIRFLOW button is pushed once, it stops swinging at an angle.
As this angle is memorized in the microcomputer, the flap will be automatically set to the angle when next operation is
started.
¡ Recommendable stopping angle of the flap
On operating in automatic operation mode by back-up switch, functions show in the above
table are not altered, white, the other micro-computer control functions remain effective.
(3) Back-up Switch
When the remote controller batteries become weak, or if the remote controller is lost or malfunctioning, this switch may be used to
turn the unit on and off.
(a) Operation
Push the switch once to place the unit in the automatic mode. Push it once more to turn the unit off.
(b) Details of operation
The unit will go into the automatic mode in which it automatically determines, from room temperature (as detected by
thermistor), whether to go into the cooling or thermal dry modes.
Function
Room temperature
Operation mode
setting
Fan speed Flap Timer switch
Cooling About 26ºC
Thermal dry About 25ºC
Auto Natural flow Continuous
Horizontal
blowing
COOL•DRY