Specifications

-
41
-
3 ELECTRICAL DATA
3.1 Electrical wiring
Models SRK06CC-1, 06CC-4, 07CC-1, 07CC-4, 09CC-1, 09CC-4
Power source
1 Phase 220/240V 50Hz
Printed circuit board
Wireless
R-Amp
Display
Indoor unit Outdoor unit
BK Black
BL Blue
BR Brown
RD Red
OR Orange
WH White
Color symbol
Operation
Cooling
Relay symbol Control part
52C CM
Table of relay operations
Symbol Parts name Symbol Parts name
C
C
Capacitor for CM LM Louver motor
CF
I
Capacitor for FM
I
Th
1
,
2
Thermistor
CF
O
Capacitor for FM
O
Tr Transformer
CM Compressor motor ZNR Varistor
F Fuse 51C Motor protector for CM
FM
I
Fan motor (Indoor unit) 52C Magnetic contactor for CM
FM
O
Fan motor (Outdoor unit)
Meaning of marks
Notes (1) : denotes magentized relay
×
: denotes demagnetized relay
(2) Th
1 is room temperature thermistor. Th2 (the heat exchanger thermistor) is frost prevention thermistor. (for details, refer to pages 47)