Specifications

71
SRK-H
2) Fan speed knob: AUTO
¡ The indoor fan is automatically controlled in accordance with the difference between the room temperature (detected
by the room temperature sensor) and the thermostat setting as shown below.
Mode
Heating Cooling Fan
18~30˚C
Thermostat setting point Thermostat setting point Thermostat setting point
Continuous Speed 5 Speed 4 Speed 3
(e) Fan control
1) Fan speed change
Set-
ting temp
Speed 2
Speed 4
Speed 1
Speed 3
Speed 3
Speed 4
Speed 2
Speed 2
Speed 3
Speed 1
Note (1) Please refer to page 73 regarding dry operation.
(5) 3 Hot system (Heat pump type only)
When initiating heating operation, restoring thermostat, defrosting operation, the indoor fan motor and the thermostat is controlled
by micro computer in accordance with the room air temp, and temp, of the indoor heat exchanger.
By this blowing of cold air is prevented and comfortable heating operation is assured.
Controls of thermostat and indoor fan motor.
Temp. that compres-
sor stops in HOT
SPURT operation
A
A
B
B
+3˚C
+1˚C
+2˚C
Temp. that compres-
sor stops in ordinary
operation
Thermo setting
RUN (HOT KEEP)
lamp flashing
Thermostat stop
Resume operation
HOT START HOT KEEPHOT SPURT
Room Temp.
Time
Indoor fan
stops
Indoor fan
stops
Expand
Defrosting operation
HOT START
HOT START
Defrosting
operation
(a) HOT START (RUN (Hot keep) lamp flashing when the indoor fan is stopped)
1) Operation timing
a) When the compressor is starting. (when starting operation and resuming operation by restored thermostat)
b) When the defrosting operation is switched to the heating operation.
Room temp.
Mode
COOL HEAT FAN
Fan speed knob
AUTO See below
LOW Speed 1 (Speed 1) Speed 2 (Speed 2) Speed 1 (Speed 1)
MED Speed 2 (Speed 2) Speed 3 (Speed 3) Speed 2 (Speed 2)
HIGH Speed 3 (Speed 4) Speed 4 (Speed 5) Speed 3 (Speed 3)
Notes (1) Please refer to page 73 regarding dry operation.
(2) Fan speeds shown in brackets are shown for when continuing with set temperatures.