Specifications
CHAPTER 6 CONNECTION OF REMOTE I/O UNIT
6.11 Connection of FCUA-DX13 Unit and Handle
87
6.11 Connection of FCUA-DX13 Unit and Handle
To connect the manual pulse generator, the R041 or R042 cable is connected to "HANDLE". Up to two
manual pulse generators can be connected. When manufacturing the R041 or R042 cable, use the
connector set CS000 (optional, with two ends). (Refer to the Appendix 11. Cable manufacturing
drawing.)
To connect one manual pulse generator
HANDLE
FCUA-DX13
12V 0V A B
Manual pulse generator
FCUA-HD60
Rear view
4-M3
NO.1
R041 cable
12V 0V A B
12V 0V A B
4-M3
SEL∗
NO.1NO.2
R042 cable
HANDLE
FCUA-DX13
1
10
11
20
Pin No.
Manual pulse generator
FCUA-HD60
Rear view
When connecting the second manual pulse generator,
connect the SEL∗ signal to the No. 1's 0V.
Incorrect connections could damage the device, so always connect the cable to the
designated connector.
Do not connect or disconnect the connection cables between each unit while the power is
ON.
CAUTION
To connect two manual pulse generators