Specifications

CHAPTER 6 CONNECTION OF REMOTE I/O UNIT
6.8 Connection of FCUA-DX10
/13
/14 Unit and Machine Control Signal
82
<Signal assignment table>
Remote I/O unit
Control unit
Communica-
tion terminal
R-TM
FCUA-DX10□/13□/14
RI02
2
1
3
LG
DCIN
+24V
12
3
FG
0V
RI01
1
2
3
LG
AMP
D-3
X
AMP
D-3
Y
AMP
D-3
DI-L
DI-L
DO-L
Machine side
control panel, etc.
0V
PL
RA
0V
24VDC(+)
0V
<CAUTION>
T X R X
T X R X*
T X R X T X R X*
X0
X0
X0
X0
X0
X0
X0
X0
X0
X0
X0A
X0
X0
X0
X0E
X0F
CO M
+24V
+24V
X1
X1
X1
X1
X1
X1
X1
X1
X1
X1
X1A
X1
X1
X1
X1E
X1F
CO M
0V
0V
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
Y0
Y0
Y0
Y0
Y0
Y0
Y0
Y0
Y0
Y0
Y0A
Y0
Y0
Y0
Y0E
Y0F
+24V
+24V
Y1
Y1
Y1
Y1
Y1
Y1
Y1
Y1
Y1
Y1
Y1A
Y1
Y1
Y1
Y1E
Y1F
0V
0V
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
DO-L
DO-L
X
When using two or more remote I/O
units or when connecting to the
communication terminal, the signal
allocation will differ.
Refer to the "PLC interface manual"
for details.
24VDC(+)
24VDC(+)
<Adaptive connector>
AMP
D-3
X
Crimp type connector:
7940-6500SC
Maker: Sumitomo 3M
Maker: Japan AMP
Connector : 1-178288-3
Contact : 1-175218-2
Maker : Japan AMP
Connector : 2-178288-3
Contact : 1-175218-5
Maker : Japan AMP
Terminator (R-TM)
RIO1/RIO2
(CN211)
DI-L/DO-L (CN300) DCIN (CN220)