Specifications
CHAPTER 6 CONNECTION OF REMOTE I/O UNIT
6.6 Outline of Analog Signal Output Circuit
79
6.6 Outline of Analog Signal Output Circuit
The analog signal output circuit can be used only for the FCUA-DX120/DX121/DX140/DX141.
Output circuit
A
0
∗
A
0
220
Ω
DAC
R
R
Output conditions
(Note) n = (2
0
to 2
11
)
Output voltage
0V~±10V (±5%)
Resolution
12 bit (±10V × n/4096) (Note)
Load conditions
10kΩ load resistance
Output impedance
220Ω