Specifications
CHAPTER 6 CONNECTION OF REMOTE I/O UNIT
6.5 Outline of Digital Signal Output Circuit
78
6.5 Outline of Digital Signal Output Circuit
The digital signal output circuit uses a sink type (DX4
0, 3
0, 2
0) or source type (DX4
1, 3
1,
2
1). Use within the specification ranges shown below.
Output circuit
Control
circuit
Sink type(DX2 0)
(DX3
0)
(DX4
0)
(
Machine side
)
R
+24VDC
DO-L/DO-R
PL
RA
Control
circuit
(
Machine side
)
+24VDC
Source type (DX2 1)
(DX3
1)
(DX4
1)
R
DO-L/DO-R
PL
RA
Output conditions
Insulation method Non-insulation
Rated load voltage +24VDC
Max. output current 60mA
Output delay time
40µs
When using an inductive load such as a relay, always connect a diode in parallel to the
load.
When using a capacity load such as a ramp, always connect a protective resistor serially
to the load to suppress rush currents.
∗ When using an inductive load such as a relay, always connect a diode (voltage
resistance 100 V or more, 100 mA or more) in parallel to the load.
∗ When using a capacity load such as a lamp, always connect a protective resistor
(R=150Ω) serially to the load to suppress rush currents. (Make sure that the
current is less than the above tolerable current including the momentary current.)
<
CAUTION
>
CAUTION