Specifications

CHAPTER 5 CONNECTION OF I/O INTERFACE
5.3 Connection of Card-sized I/O
61
(3) Output circuit
The HR361 output circuit is a sink type (sink output), and the HR371 output circuit is a source type
(source output).
+24V
RA
R
PL
GND
HR371
GND
+24V
HR361
RA
R
PL
GND
Sink type
Source type
Control
circuit
Control
circuit
(Machine side) (Machine side)
CF30
CF30
Do not apply voltages other than those indicated in this manual on the connector. Doing
so may lead to destruction or damage.
(4) Output conditions
Output current 60mA/point
Saturated voltage
(HR371 only)
1.6V (standard)
Output delay time
40µs
CAUTION
When using an inductive load such as relays, always connect a diode (withstand voltage
100V or more, 100mA or more) in parallel to the load as a noise measure.
When using a capacitive load such as a lamp, always connect a protective resistor
(R=150) serially to the load to suppress rush currents. (Make sure that the current,
including the instantaneous current, is less than the above tolerable current.)