Specifications
APPENDIX 3 EMC INSTALLATION GUIDELINES
5. Measures for Wiring in Panel
126
(2) Example of grounding connection for M6
0 Series
Main grounding plate
of distribution panel
R220 cable
(24VDC cable)
0V
Short bar
FG cable
200VAC input
FCU6-DX
Base I/O unit
FG cable
AC input
Stabilized
power supply
SH21 cable
(for NC AMP)
F010 cable
0
0
CF31 CF32
CF34
CF33
SV2
SV1
HR3□□
RI O1RI O2
DCIN
CF10
EN C
CR31
SKI P
0
J2 CF11CF12
CON1
CF21
CF22
K/BMOUSE
HANDLE
RIO3
Control unit
FCU6-MU
Display unit
FCU6-DU
NC keyboard
FCU6-KB
FG cable
FG cable
FG cable
FG cable
R220 cable
(24VDC cable)
24VDC
(+)
FG
Operation panel
Control panel