Service manual

190 / 195
Service Manual Mitsubishi SL-Series diesel engines
Version 08/2004
ENGLISH
SPECIFICATIONS SERVICE DATA
190 / 195
Alternator
Regulated voltage at 20°C (68°F) 14.7 ± 0.3 V
Output
charac-
teristics
(at
operating
tempe-
rature)
At 2500
rpm
Terminal
voltage
13.5 V
Test.
Current 33 A min.
At 500
rpm
Terminal
voltage
13.5 V
Current 47 A min.
Brush length Wear limit line Replace.
Resistance in glow plug 0.55 Replace.
Item Standard Limit Correction-Remarks