Hardware manual
Chapter2 Connection to a PLC
2-326
FLEX-PC Communication Setting
When you would like to set up the communication setting with the initialization file, refer to the
following setup.
Set up item of 4, 5, 6, and 7 as well as MICRO/I settings.
N
o.
Item 0 1 2 3 4 5 6 7
1 Transmission
type
Nonse
quenc
ed
format
2 Mode Setting
3 Received
Message No.
0
4 Baud rate 1200 2400 4800 9600 19200
5 Data bit size 7 8
6 Parity bit None Odd Even
7 Stop bit size 1 2
8 DCE/DTE mode DTE
9 CTS/RTS
control
Consta
ntly
ON
10 DSR/DTR
control
Consta
ntly
ON
11 Transmission
conditions
None
13 Transmission
code
JIS
14 Code
conversion
Yes
15 Received data
byte size
0
16 Start code STX
17 End code CR
18 Start code 1,2 0
19 End code 1,2 0
20 BCC Setting
1
21 Position (range) TEXT
22 Calculation
formula
EOR
23 Code Trans-
missio
n code
24 Timer