Hardware manual

Chapter2 Connection to a PLC
2-306
17.4 Environment Settings
17.4.1 YOKOGAWA FA-M3
YOKOGAWA FA-M3 - Link Unit (F3LC11-1N, F3LC112N) to MICRO/I Setting
Items Details
Serial Interface RS-232C RS-485 (4wire)
CPU Number 01(0x01) – 4(0x04)
Station Number 01(DEC)
Baud Rate (bps) 9600/19200
Data Bits (bit) 7,8
Parity Odd/Even/None
Stop Bits (bit)
Use the same
settings as for the
MICRO/I.
1 / 2
Sum check Enable
Terminus character specification Enable
Protection function Disable
YOKOGAWA FA-M3 CPU (Programming tool port) to MICRO/I Setting
Items Details
Serial Interface RS-232C
Station Number 01(DEC) (Fixed)
Baud Rate (bps) 9600/19200
Data Bits (bit) 8 (Fixed)
Parity Even/None
Stop Bits (bit)
Use the same
settings as for the
MICRO/I.
1 (Fixed)
Sum check Enable
Terminus character specification Enable