Hardware manual

Chapter2 Connection to a PLC
2-266
13.4 Environment Settings
13.4.1 AROMAT FP series
13.4.1.1 FP0 and FP1 (tool port on CPU unit).
Items Details
Serial Interface RS-232C RS-422(4wire)
Slave Address 01 – 99(DEC) (*1)
Baud Rate (bps) 9600/19200
Data Bits (bit) 8
Parity Odd
Stop Bits (bit) 1
Flow Control
Use the same
settings as for the
MICRO/I.
Hardware/None
(*1) There are some models that don’t support Slave Address up to 99.
13.4.1.2 FP1 (RS-232C port on CPU unit)
Items Details
Serial Interface RS-232C
Slave Address 01 – 99(DEC)
Baud Rate (bps) 1200/2400/4800/9600/19200
Data Bits (bit) 7,8
Parity None, Even, Odd
Stop Bits (bit) 1 / 2
Flow Control
Use the same
settings as for the
MICRO/I.
Hardware/None
13.4.1.3 FPΣ (Tool port on CPU unit or communication cassette)
Items Details
Serial Interface RS-232C RS-485(2wire)
Slave Address 01 – 99 (DEC)
Baud Rate (bps) 2400/4800/9600/19200/38400/57600/115200
Data Bits (bit) 7,8
Parity None, Even, Odd
Stop Bits (bit) 1 / 2
Flow Control
Use the same
settings as for the
MICRO/I.
Hardware/None