Hardware manual
Chapter2 Connection to a PLC
2-186
7.4.2 Using Communication Port
Item Setting
Communication Method RS-232C RS-485(422)
Station No. 001 to 037(oct)
(Set System Memory #235/#237)
Data Bits[bit] 7(fixed)
Baud Rate [bps] 1200/2400/4800/9600/19200/38400/57600/115200
(Set the bit position D
2
D
1
D
0
System Memory of #234/#236)
Parity Even / Odd / None
(Set the bit position D
4
D
3
of System Memory #234/#236)
Stop Bits [bit]
Set to the same
setting as the
MICRO/I
1/2
(Set the bit position D
5
of System Memory #234/#236)
- Set System Memory #234 for communication conditions of PLC (JW30 Communication
port1:RS-422), and set System Memory #235 for Station No..
- Set System Memory #236 for communication conditions of PLC(JW20/70/100
Communication port,JW30 Communication port2:RS-232C/RS-422 ), and set System
Memory #237 for Station No..
- Confirm the PLC manuals as the speed of Baud Rate may not use according to PLC.
- When connecting with the communication port of a CPU unit and making it communicate,
after receiving a response from PLC depending on the model of PLC, while MICRO/I
transmit data, some which need waiting time are.
- In this time, please adjust [File]-[Project Settings]-[Host Port]-[transmission wait] of
WindO/I-NV2.
- Confirm the manual.(chapter of a communication port) of PLC about whether a
[transmitting weight] setup need to be adjusted.
- Refer to “ New Satellite JW manual“ or “New Satellite JW Link Unit manual” for details.