4.6.4 Setting Example for WindO/I-NV2
Refer to the following about setting example for WindO/I-NV2 software.
(PLC station number is 0 in the example.)
*The setting example use Allen-Bradley device address format.
Tag name Type Array File Number
Tag_A INT - 1
Tag_B SINT [10] - 2
Tag_C DINT [10] - 3
Tag_D REAL [10] - 4
Example1: Set an array number 0 in Tag_A.
0: INT 1:0
Example2: Set an array number 5 in Tag_B.
0: SINT 2:5
Example3: Set a lower word on array number 3 in Tag_C.
0: DINT 3:3_0
Example4: Set an upper word on array number 9 in Tag_D.
0: REAL 4:10_1
Note:
Need to set upper word or lower word in WindO/I-NV2 software when use 32 bit device.
Add “_0” after array number when use lower word.