CHAPTER 3 COMMUNICATIONS BY THE MODEM FUNCTION
3
3.3 Specifications
(2) Specification and precautions for the connectable TA's (terminal adapters)
(a) TA specification
*1 TA's that turn on the CD (DCD) signal simultaneously cannot be used.
Use a TA capable of flow control as described in Page 83, Section 3.3.2 (1) (a) also for the communication between the
TA and terminal. Flow control is a function of the TA itself that becomes available by issuing the AT commands to the
modem. See the TA manual for details.
(b) Precautions for selecting a TA
Set the TA on the Q series C24 side as listed below:
*1 Some TAs may transmit one character as 10 bits. Check the TA specifications when setting the Q series C24
transmission specifications.
*2 Some TAs may switch the communication rate following the start of data communication. Since the Q series C24 cannot
switch the communication rate, set the TA side so that its communication rate does not switch.
When using a TA whose DR terminal (signal) is set by a switch, set the DR-terminal (TA output) switch level
to high. When using a TA requiring DR terminal setting with software, write the command that turns on the
DR (DSR) signal into the data for initialization. Set the "Modem initialization time DR signal valid/invalid
designation" to "Invalid" during modem function system settings with GX Configurator-SC.
Item Specifications Remarks
TA-to-TA communication
specification
Connection line ISDN (INS net 64) equivalent, High-speed digital dedicated line DSU and TA are required
Initialization Hayes AT command compatible Page 134, Section 3.4.3
Communication standard B-channel line exchange (V.110), D-channel packet exchange
Electrical condition V.28 compliant
Q series C24-to-TA
communication
specification
Circuit definition V.24 compliant
Q series C24-side
connector (RS-232)
9-pin (female) D sub User's Manual (Basic)
DR signal control Only the DR (DSR) signal must be able to turn on
*1
Other Compatible with the Q series C24 specification
Page 82, Section 3.3.1,
User's Manual (Basic)
Setting item Setting range
Communication rate Depends on the TA in use
TA command Hayes AT command
SI/SO control None
Communication method No procedure
Data format
Data bit
Match the Q series C24
*1*2
Stop bit
Parity bit