CHAPTER 2 USING THE PROGRAMMABLE CONTROLLER CPU MONITORING FUNCTION
2
2.2 About the Programmable Controller CPU Monitoring Function
(d) The user frame numbers that can be designated for data transmission of
programmable controller CPU monitoring results are listed below.
• 1H to 3E7H (Default registration frame numbers)
• 3E8H to 4AFH (Frame numbers registered by the user in the flash ROM)
• 8001H to 801FH (Frame numbers registered by the user in the buffer memory)
• B001H to B01FH (Dedicated frame numbers for this function listed in Page 47, Section 2.2.5 (2) (e) below)
For details on how to designate user frame numbers, see Transmission using user frames in Page 252,
CHAPTER 11.
(e) For instructing to transmit the device information and programmable controller CPU
status information when sending monitoring results as data, use the following
dedicated user frame numbers.
Frame number Information to be transmitted
Valid function
Constant cycle
transmission
Condition agreement
transmission
B001H
Device information for the block registered
in number n
Number 1
B002H Number 2
B003H Number 3
B004H Number 4
B005H Number 5
B006H Number 6
B007H Number 7
B008H Number 8
B009H Number 9
B00AH Number 10
B061H
Programmable controller CPU status information (CPU abnormal
monitoring data)
B080H Number of blocks sent
B081H Monitoring result information for all blocks
B082H Monitoring result information for blocks satisfying the conditions