User`s manual
398
17.7 G(P).PUTE
This instruction registers a user frame.
17.7.1 Setting data
The file registers of each of the local device and the program cannot be used as the setting data.
17.7.2 Control data
Setting
data
Applicable device
Internal device
File register
Link direct device
J\
Intelligent function
module device
U\G
Index register Zn Constant Others
Bit Word Bit Word
(S1)
(S2)
(D)
Setting data Description Set by Data type
Un
Start I/O signal of the module
(00 to FE: The 2 upper digits of an input/output signal expressed in 3-digit.)
User BIN-16 bit
(S1) Head number of the devices that store control data User, System
Device name
(S2) Head number of the devices that store registered data
System
(D)
Head bit device number of the local station that turns ON for one scan upon instruction
completion.
(D)+1 also turns on if the execution completes abnormally.
Bit
Device Item Setting data Setting range Set by
(S1)+0 Register/delete designation
Designate whether to register or delete the user frame having
the number designated by (S1)
Register: 1
Delete: 3
1, 3 User
(S1)+1 Register/delete result
The registration/deletion result by the PUTE instruction is
stored.
0: Normal
Other than 0: Error code
System
(S1)+2 Frame No. Designate the user frame No. 1000 to 1199 User
(S1)+3 Registered bytes count
1 to 80: Number of bytes of the user frame to be registered.
• Designate 1 to 80 as dummy when deleting.
1 to 80 User
GP.PUTE
G.PUTE
GP.PUTE
G.PUTE
(S1) (S2)
Un
(D)
(S1) (S2)
Un
(D)
Command
[Executing
condition]
[Instruction
code]
Command