CHAPTER 3 COMMUNICATIONS BY THE MODEM FUNCTION
3
3.5 Sample Programs
(3) Sample program for a connection receiving station side (QJ71C24-R2 2))
After the connection in progress signal (x12) = ON, data communications are carried out by the non procedure
protocol through a command from the user.
Perform the following settings before running this program.
(a) GX Developer switch settings ( Page 131, Section 3.4.2)
(b) Settings by GX Configurator-SC ( Page 131, Section 3.4.2)
Perform the following settings in each setting screen.
Use the default settings in screens and setting items other than those listed below.
Modem function system settings
Switch No. Setting value
Switch 1 07E2
Switch 2 0006
Switch 5 0000
"Modem function system setting" screen setting items Setting value
Modem connection channel designation 1CH
Data No. for initialization designation 07D5
Auto modem initialization designation Auto initialize