User`s manual
166
Access possible
Data communications possible
Data transmission possible
Line disconnect possible
<Status confirmation>
<Modem initialization, line connection processing>
<Data transmission processing (non procedure protocol)>
<Data reception processing (non procedure protocol)>
Modem initialization, line connection
possible
Conversion of modem initialization,
line connection commands to pulses
Modem initialization, line connection
processing to sub routine
Conversion of data communications
(transmission) commands to pulses
To the data transmission processing
sub routine
Setting of the receive data reading
request
To the data reception processing rub
routine
Conversion of line disconnect
commands to pulses
Conversion of turning connected
signals OFF to pulses
To the line disconnect processing sub
routine
<Line disconnect processing>