User`s manual
157
CHAPTER 3 COMMUNICATIONS BY THE MODEM FUNCTION
3
3.4 Start-up of the Modem Function
(b) When notifying to pager receiver
• Initial setting by GX Configurator-SC
Register the data number registration area for connection below in the "Modem function system setting"
screen.
BB8H to BD5H (3000 to 3029): Data registered to the Flash ROM by the user
8001H to 801FH (-32767 to -32737): Data registered to the buffer memory by the user
• I/O signal
Use notification-issued request signal (Y14), notification normal complete signal (X15), notification abnormal
complete signal (X16).
When normal completion
(OFF)
(ON)
0
0
3000
10
0
3000
X10
X12
X15
X16
Y14
(OFF)
Initialization
completion
Connection in
progress
Notification
normal completion
Notification
abnormal completion
RS-232 CD terminal
Dial
Notification-
issued request
Notification
Disconnection
Notification execution data
storage area
(Address: 22AH (554))
Modem function error code
storage area
(Address: 221H (545))
Buffer memory for notification
Data number for
connection designation area
(Address: 35H (53))
Buffer memory for Q series C24 initial setting
Notification execution
designation area
(Address: 2FH (47))
…… ……