User`s manual

137
CHAPTER 3 COMMUNICATIONS BY THE MODEM FUNCTION
3
3.4 Start-up of the Modem Function
(b) For the buffer memory of the Q series C24
The initialization data write (registration) and read operations are performed by designating an applicable
area that corresponds to registration numbers 8001H to 801FH for the user frame registration area
(addresses: 1B00H to 1FF6H). When deleting the initialization data, write "0" to the number of registration
data bytes designation area.
The table below shows an overview of the buffer memory used in the write, read, and delete operations of
the initialization data as well as the designated values for each area. For more details, see Page 220,
CHAPTER 9. (Use the table by replacing the user frame with the initialization data.)
The contents of the data to be written into the designated area that corresponds to registration numbers
8001H to 801FH are the same as those for the Flash ROM.
Address
Name Designated/stored value
Specification required
()/not required ()
Hexadecimal Decimal Write Read Delete
1B00H 6912
Registration
number
8001H
Registration data byte
number designation
0: When deleting
1 to 78: Number of bytes in the registration data
(Only for the initialization command section)
(Read
processing
not
required)
1B01H 6913 User controlled data
Any data used by the user to manage the registration
data (manufacturer code, control number, etc.)
1B02H 6914
Initialization
command
Data code for the initialization command for registration
1B28H 6952
1B29H 6953
Registration
number
8002H
Registration data byte
number designation
0: When deleting
1 to 78: Number of bytes in the registration data
(Only for the initialization command section)
(Read
processing
not
required)
1B2AH 6954 User controlled data
Any data used by the user to manage the registration
data (manufacturer code, control number, etc.)
1B2BH 6955
Initialization
command
Data code for the initialization command for registration
1B51H 6993
1FCEH 8142
Registration
number
801FH
Registration data byte
number designation
0: When deleting
1 to 78: Number of bytes in the registration data
(Only for the initialization command section)
(Read
processing
not
required)
1FCFH 8143 User controlled data
Any data used by the user to manage the registration
data (manufacturer code, control number, etc.)
1FD0H 8144
Initialization
command
Data code for the initialization command for registration
1FF6H 8182