User`s manual

130
(4) If accessing the QCPU from GX Developer
*1 Page 86, Section 3.3.3
*2 Page 92, Section 3.3.4
0
1
2
3
4
5
3
*
*
Q Series C24
GX Developer (Line connection side)
Modem Modem
Registration of the modem connected
to the personal computer
Registration complete
Connect to the line after setting the
necessary items in the line connection screen.
Line connection normal response
Password check (for the system)
Normal response
Line connection
Line disconnect processing by
the line disconnect screen.
Line disconnect response.
Line Disconnect
Modem initialization
Line connection wait state
Modem initialization completed
signal (X10) = ON
Line disconnect response
Connection in progress signal
(X12)=OFF
Line connection wait state
Modem initialization completion
signal (X10)=ON
Line connection normal response
Connection in progress signal
(X12)=ON
indicates processing
performed by the user.
Perform the processing up to the
point where the modem/TA is
initialized by the procedure in (1).
Initialize the personal computer
side modem.
Execute line connection.
Access to the QCPU.
Execute line disconnect.
Access to the QCPU
If the callback function is used
*2
Remote password check
*1
Shows the value stored for the modem function sequence status
(address 546 (221H))
When setting the remote password in
the QCPU, the remote password input
dialog box is displayed.