User`s manual
App - 2 App - 2
MELSEC-Q
APPENDIX
Appendix 1.2 Combinations of D/A converter module functions and GX Configurator-DA
software versions
The following table indicates the D/A converter module functions and corresponding
GX Configurator-DA software versions.
Software version
Function
SW0D5C-QDAU-E
00A
SW0D5C-QDAU-E
10B
GX Configurator-DA
Version 1.10L to 1.15R
GX Configurator-DA
Version 1.16S or later
Normal resolution mode
High resolution mode
1
High resolution mode status
flag (X8)
1
2
Multiple PLC system
compatibility
1
Analog output test during
PLC CPU STOP
1
Normal mode - offset/gain
setting mode switching
3
: Compatible : Not compatible
1 Functions added by function version B.
2 When the D/A converter module is function version A and the GX Configurator-DA
software version is SW0D5C-QDAU-E 20C or later or GX Configurator-DA
Version 1.10L or later, OFF is always displayed.
3 Functions added by function version C.