User`s manual

6 - 9 6 - 9
MELSEC-Q
6 PROGRAMMING
(2) Operating the utility package
(a) Initial setting (see Section 5.4)
CH1, CH2 D/A conversion enable/disable setting ...."Enable"
CH1 rate control enable/disable setting....................."Enable"
CH1 increase digital limit value.................................."100"
CH1 decrease digital limit value ................................"30"
CH1 disconnection detection setting ........................."Enable"
CH2 warning output setting........................................"Enable"
CH2 warning output upper limit value........................"10000"
CH2 warning output lower limit value ........................"3000"
(b) Auto refresh setting (see Section 5.5)
CH1, CH2 digital values.............................................W11, W12
CH1, CH2 output monitor values...............................W113, W114
Disconnection detection.............................................W115
Warning output ...........................................................W116
Error code...................................................................W117
(c) Write of intelligent function module parameters (Refer to Section 5.3.3)
Write the intelligent function module parameters to the CPU module.
Perform this operation on the parameter setting module selection screen.