Service manual
26
<DRY operation time chart>
Minimum 3 minutes w1
ON
30
Thermostat
Indoor fan
Auto vane
Drain pump
Booster heater
Compressor
ON
ON
LOW speed
Initally 30 degrees discharge
(
Changeable by remote controller setting
)
LOW speed
ON
ON
OFF
OFF
discharge
position
3 minutes
OFF
OFF
OFF
OFF
Operation starts by
POWER button
ON.
Operation stops by
POWER button
OFF.
Room temperature
becomes equal to
set temperature.
Room temperature
rises above set
temperature.
30
discharge
position
w1 Even if the room temperature rise above the set temperature during this period, the compressor will not start until this period has ended.
2-2 DRY operation
(1) Compressor control
13-minute time delay
To prevent overload, the compressor will not start within 3 minutes after stop.
2The compressor runs when the room temperature is higher than the set temperature.
The compressor stops when the room temperature is equal to or lower than the set temperature.
3The compressor stops in check mode or during protective functions.
FILTER
CHECK MODE
TEST RUN
240KA
<How to operate>
1 Press POWER ON/OFF button.
2 Press the button to display “ ”
3 Press the TEMP button to set the desired temperature.
NOTE: The set temperature changes 1°C when the or
button is pressed one time.
Heat 19 to 30°C