Service manual
24
(3) Auto vane control
Auto vane position is set to 35degrees airflow at the start-up of COOL operation. It can then be changed by the remote
controller.
(a) Stop mode (fixed operation)
( i ) At start-up of COOL operation, the auto vane is set to 10 degrees air flow direction.
( ii) Airflow direction can be changed with botton.
(b) SWING mode
( i ) The vane motor turns ON when the SWING mode is selected.
The vane motor is continuously ON during SWING mode.
When 55 degrees or 70 degrees air flow is selected with the LOW fan speed in COOL operation, “AUTO RETURN” will
appear below the temperature display. One hour later, the air flow direction returns to 30 degrees automatically and “AUTO
RETURN” will disappear. If the air flow direction is set to 30 degrees during “AUTO RETURN” indication, the time counting
for AUTO RETURN is cancelled.
1 Fan speed : LOW
2 Fan speed : HIGH
30°
55°
70°
30°
55°
70°
SWING
SWING
(SW5-3:OFF/ON)
(SW5-3:OFF/ON)
45°
30
30
55
45
70
AUTO RETURN AUTO RETURN
55
70
<AUTO RETURN>
1 Fan speed : LOW
2 Fan speed : HIGH