Service Manual

75
Function
Settings
No.
Mode
No.
Setting
: Initial setting
(
Factory setting
)
- : Not available
4-Way
cassette
Wall
mounted
PKA-GA(L)
PKA-FA(L)
Filter sign
100h
1
2500h
07 2
"Clean the filter" indicator is not displayed
3
Air flow
Quiet
1-
(
Fan speed
)
Standard
08 2 -
High ceiling
3-
No.of air outlets
4 directions
1-
3 directions
09 2 -
2 directions
3-
Optional high efficiency
Not supported
10
1
-
filter
Supported
2
-
Vane setting
No vanes (Vane No.3 setting : PLA only)
1-
Vane No.1 setting
11 2 -
Vane No.2 setting
3-
Optional humidifier
Not supported
13
1
-
(
PLA only
)
Supported
2
-
Vane differential setting
No.1 setting (TH5: 24-28)
1
in heating mode
No.2 setting (Standard, TH5:28-32)
14 2
(
cold wind prevention
)
No.3 setting (TH5: 32-38)
3
Swing
23
1
2
Set temperature in heating
24
1
mode
(
4 degC up
) +1
2
Fan speed when the
Extra low
1
heating thermostat is OFF
Stop
25 2
Keeping fan speed set by remote controller
3
Fan speed when the
Keeping fan speed set by remote controller
27
1
cooling thermostat is OFF
Stop
2
Detection of abnormality of
Detect
28
1
the pipe temperature
(
P8
)
Neglect
2
PLA-BA
Not available Swing
Available Wave air flow
Available
Not available
}
PLA-BA
PKA-HA
PKA-HAL
-
-
-
-
-
-
-
-
-
-
-
PKA-KA
PKA-KAL
-
-
-
-
-
-
-
-
-
-
-
Ceiling
Suspended
PCA-KA
-
-
-
-
-
(2) Functions available when setting the unit number to 01-03 or AL (07 in case of wireless remote controller)
• When setting functions for an indoor unit in an independent system, set the unit number to 01 referring to 4 setting the
indoor unit number.
• When setting functions for a simultaneous twin indoor unit system, set the unit number to 01 to 03 for each indoor
unit in case of selecting different functions for each unit referring to 4 setting the indoor unit number.
• When setting the same functions for an entire simultaneous Twin-indoor unit system, set refrigerant address to AL
(07 in case of wireless remote controller) referring to 4 setting the indoor unit number.
Mode No.11
Setting No. Settings PLA-BA
1
Vane No.3 setting
(
Downward position than the standard
)
Less smudging
2 Vane No.1 setting Standard
3 Vane No.2 setting
(
Upward position than the standard
)
Less draft *
* Be careful of the smudge on ceiling.
PCA-KA
No vane function
Standard
Less draft *
(
Upward position than the standard
)
w
1. PKA-HA(L)/KA(L): 2degC (3.6degF) up