Service manual

6
4 SPECIFICATIONS
Item
Service Ref.
PK-1.6FLA
3 PK-2FLA3
PK-2FLA3
PU-2VJA2
Single, 50Hz, 220/240V
2.44 / 2.48
11.3 / 10.8(98/96)
48 / 52
PU-2NJA
1
Single, 60Hz, 220V
2.45
11.4(98)
54
2.97
13.6(99)
54
Munsell 5Y 7/1
Capillary tube
Hermetic
Line start
Inner thermostat, HP/LP switch
Plate fin coil
Propeller (direct) o 1
0.065
45 (1588)
870 (34-1/4)
295 (11-5/8)
650 (25-5/8)
60 (132)
9.52 (3/8)
15.88 (5/8)
Flared
Flared
w3 Max. 20m
w3 Max. 30m
49 50
32 / 38
R-22 1.78 (3.9)
R-22 1.9 (4.2)
NHJ41VMD
2.0
NHJ33NBD
1.5
Single, 50Hz, 220/240V
0.08
0.37(98/90)
0.4
Munsell 3.4Y 7.7/0.8(White)
Plate fin coil
Line flow (direct) o 1
0.030
10-14 (353-459)
0 (direct blow)
Wireless remote controller & Built-in
38 - 45
20 (13/16)
1,250 (49-3/16)
200 (7-7/8)
300 (11-13/16)
17 (37)
Single, 60Hz, 220V
0.09
0.42(97)
0.5 0.5
w6
w7
16,000
4,600
3.06
19,000
5,450
2.54
27/19.0°C, 35/24°C
Cooling (JIS B8616)
19,100
5,600
2.52/2.56
27/19.0°C, 35/24°C
Cooling (JIS B8616)
13,300
3,900
1.49/1.59
PK-1.6FLA
3
Single, 50Hz, 220/240V
0.07
0.32(99/91)
0.4
Munsell 3.4Y 7.7/0.8(White)
Plate fin coil
Line flow (direct) o 1
0.030
10-13 (353-459)
0 (direct blow)
Wireless remote controller & Built-in
36 - 43
20 (13/16)
1,250 (49-3/16)
200 (7-7/8)
300 (11-13/16)
17 (37)
PU-1.6VLJA
2
Single, 50Hz, 220/240V
1.42 / 1.52
6.7 / 6.9 (97/92)
30 /33
Munsell 5Y 7/1
Capillary tube
Hermetic
RH247VFC
1.2
Line start
w4
Plate fin coil
Propeller (direct ) o 1
0.065
45 (1588)
49
870 (34-1/4)
295 (11-5/8)
650 (25-5/8)
45 (99)
R-22 1.3 (2.9)
9.52 (3/8)
15.88 (5/8)
Flared
Flared
w3 Max. 15m
w3 Max. 20m
Condition
Capacity w1
Total input w1
Service Ref.
Power supply(phase, cycle,voltage)
Input
Running current (Power factor)
Starting current
External finish
Heat exchanger
Fan(drive) o No.
Fan motor output
Airflow (Low-High)
External static pressure
Booster heater
Operation control & Thermostat
Noise level (Low-High) w2
Cond. drain conn. O.D.
Dimensions
Weight
Service Ref.
Power supply (phase, cycle, voltage)
Input
Running current (Power factor)
Starting current
External finish
Refrigerant control
Compressor
Model
Motor output
Starter type
Protection devices
Heat exchanger
Fan(drive) o No.
Fan motor output
Airflow
Defrost method
Noise level w2
Dimensions
Weight
Crankcase heater
Refrigerant Charge
Pipe size O.D.
Connection method
Between the indoor &
outdoor units
Btu/h
W
kW
kW
A (%)
A
kW
m
3
/min(CFM)
Pa(mmAq)
kW
dB
mm(in.)
mm(in.)
mm(in.)
mm(in.)
kg(lbs)
kW
A(%)
A
kW
kW
m
3
/min(CFM)
dB
mm(in.)
mm(in.)
mm(in.)
kg(lbs)
W
kg(lbs)
mm(in.)
mm(in.)
Indoor, Outdoor D.B./W.B.°C
Liquid
Gas
W
D
H
W
D
H
REFRIGERANT PIPING
OUTDOOR UNIT
Indoor side
Outdoor side
Height difference
Piping length
INDOOR UNIT
1. STANDARD SPECIFICATION
w1 Refrigerant piping length (one way) : 5m (16ft)
w2 Noise level is measured in an unacoustic room based on JIS conditions.
w3 Up to 20m it is unnecessary to charge additional refrigerant.
w4 Inner thermostat, HP/LP switch.
w5 Motor protector, Thermal switch, HP/LP switch.
w6 Indoor, Outdoor D.B./W.B. : 29/19°C, 46/24°C
w7 Cooling SSA385, 386
OC129A-1.qxp 01.10.1 7:33 PM Page 6